Skip to content

A leading firmsince 2001

עבריתעב077-670-4444
4.9 · 55 real reviews on Google

Doors and signage

Written by the engineers of Arad Bedek Bayit, led by engineer Ron Arad

On this page · 3
  1. Fire doors
  2. Lobby door
  3. Signage

A building has two types of doors: fire doors, which are made of metal, and ordinary exit doors, which are usually made of glass.

The upper corner of a dark aluminum frame on the building's entrance door

A fire door with a hydraulic door closer, and a lit exit sign above it

Fire doors

Fire doors are meant to separate areas, so that fire does not spread from one area to another.

For example: a floor lobby in a high-rise building is often separated into three fire zones. Two zones, on either side of the lobby, include the entrances to the apartments and the entrance to the stairwells, and a third zone in the middle includes the elevators.

Fire doors that are in the "normally open" position and held by magnets are released automatically in an emergency and close, and in this way they protect the areas without fire or smoke.

The inspection of the fire doors includes, among other things, how they operate in an emergency, their leveling (to make sure they close properly, without gaps larger than the standard allows), the finish and more.

It is important to know: in the stairwells, which serve as the escape route from the building in an emergency, the doors must close even when the pressurization fan is forcing air into the stairwell under pressure.

If the doors are not balanced against this pressure, they will not close, the air will escape from the stairwell, the pressure in it will drop, and smoke will be able to get in. More about this on the page stairwell.

Lobby door

Problems are often found in the main or secondary lobby door. They can be of different kinds: from a wind tunnel created by poor design of the openings into the building, to an aluminum structure that is too weak and makes the door sag.

Wind tunnel

A wind tunnel forms when a strong wind comes in from one direction and goes out through another opening. The result: the door closes or opens with great force, the user loses control and can be hurt. The defect comes from poor design that does not take into account the wind directions relative to the location of the building's openings. The phenomenon can cause injury, especially to children and the elderly.

The solution is a wind barrier, which changes the flow of the wind at the entrance to the building. Details and an example on the page lobby door.

Sagging door

Lobby doors are usually made of a strong aluminum structure, which also supports the adjoining glass wall (vitrine).

Sometimes it turns out that over time, after hundreds of openings and closings, the door starts to sag or tilt. This happens because of poor design of the aluminum structure, or because of poor installation.

Signage

Today the Planning and Building Regulations are strict about signage. It may seem a minor detail, but wrong or missing signage can endanger lives.

For example, every exit inside the building must have an exit sign lit by emergency lighting. Suppose that in an emergency there is also a power outage, and a person is escaping through the stairwell. A clear, lit exit sign will show him on which floor to open the door, leave the stairwell and continue out of the building.

The engineers of Arad Bedek Bayit, led by building engineer Ron Arad, whom courts appoint as their own expert on construction defects. The company has been inspecting apartments and buildings since 2001. Engineer Ron Arad · More about the company

Real reviews on Google

4.9 out of 5 · 55 reviews

  • Arad Bedek Bayit prepared an engineering expert opinion to our satisfaction and brought about success in our lawsuit against the contractor… Warmly recommended

    Sharon Elkayam · a claim against a contractor

  • Professional, thorough, and excellent service throughout the process. A must for every apartment buyer. Highly recommended

    Ef Ya · buying an apartment

  • …Contractors regard Arad's reports as reliable, so it is relatively very easy to deal with them when it comes to getting the defects handled. Highly recommended

    Shalom Maoz · building committee and private client

  • …He found several flaws I had not noticed and, most important, moisture in a kitchen cabinet caused by a poorly sealed water pipe…

    Yonatan Y · new apartment

  • After a thorough survey, and after going through sample reports from several inspection companies, I chose Arad Bedek Bayit…

    Orit Horowitz · compared reports

  • …Thanks to them we made several essential repairs in the apartment we bought, things we had not seen and did not know about…

    Reut Azriel-Ifergan · dampness and resale

  • The engineer arrived on time, checked the apartment down to the smallest detail and came across as very thorough… much more than just a report.

    Arnon Meiri · building inspection

  • …The real solution to dampness and mold problems is found only with engineers who examine things in depth, professionally and objectively.

    Y. Bril · dampness and mold

  • Arad carried out a comprehensive inspection of the apartment for us before we bought it. The engineer was very courteous and professional, explained everything…

    Michal Torky · before buying